   Dimensions( mm):  
 

DN

D1

D2

Z-~d

L

H

PN10

PN16

PN10

PN16

PN10

PN16

50

165

165

125

125

4-19

4-19

203

395

65

185

185

145

145

4-19

4-19

216

405

80

200

200

160

160

8-19

8-19

241

430

100

220

220

180

180

8-19

8-19

292

510

125

250

250

210

210

8-19

8-19

330

560

150

285

285

240

240

8-23

8-23

356

585

200

340

340

295

295

8-23

8-23

495

675

250

395

405

350

355

12-23

12-23

622

730

300

445

460

400

410

12-23

12-28

698

760

350

505

520

460

470

16-23

12-28

787

840

400

565

580

515

525

16-23

16-28

914

910

450

615

640

565

585

20-28

16-31

978

910

500

670

715

620

650

20-28

20-31

978

750

600

780

840

725

770

20-31

20-34

1230

850

  Main Technical Features  
 

PN

1.0MPa

1.6MPa

2.5MPa

Shell Test

1.5MPa

2.4MPa

3.75MPa

Seal Test

1.1MPa

1.76MPa

2.75MPa

Suitable Temperature

《80oC

Suitable Medium

Water

 
 

9.Emergency Shut-Off Valve

 
   
  Product Specification:  
             The 800X pressure difference balance valve is a kind of valve intended for use between the water supply part and the return water
part of an air conditioning system to balance the pressure difference.


         The 900X emergency shut-off valve belongs to a kind of valve that is intended for use in a water supply system in which the fire fighting water and domestic water are connected in parallel and for the control of the direction of water supply. When a fire breaks out and a large
quantity of water is in great need for fire fighting purpose, the 900X emergency shut-off valve cuts off the domestic water supply
immediately so as to ensure enough fire fighting water. When the fire fighting is over and the pressure in terms of water use has dropped,
the valve switches on automatically to stay in the constantly open state and the normal domestic water supply is restored. This valve
makes it unnecessary to set a separate fire fighting water supply network in the system, thereby greatly reducing the construction cost
and water consumption. Furthermore, the valve is high in control sensitivity, safe, reliable, simple to debug and offers a long service life.
Pressure Rating: PN10. PN16. PN25/Class150Size Range: DN20mm-DN800mm (3/4" - 32")Test and inspection: GB/T 13927 API598
 
  Main Technical Features  
 

PN

1.0MPa

1.6MPa

2.5MPa

Shell Test

1.5MPa

2.4MPa

3.75MPa

Seal Test

1.1MPa

1.76MPa

2.75MPa

Suitable Temperature

《80oC

Suitable Medium

Water

 
  Dimensions( mm)  
 

DN

20

25

32

40

50

65

80

100

125

150

200

250

300

350

400

450

L

150

160

180

200

203

216

241

292

330

356

495

622

698

787

914

978

H1

247

247

247

278

278

298

313

350

365

420

450

470

490

526

570

570

H

342

342

342

395

395

405

430

510

560

585

675

730

760

840

910

910

 
        Page Up       Page Down
 
 
Copyright © 2008-2010 Add:Room804,No.1288 XingSong RD,Songjiang District,Shanghai,China.
Tel:0086-21-56525566 0086-21-56525577  Fax:0086-21-56098787  E-mail:dzv@dazhong-valve.cn  Supported by:www.wz666.com